Supply & Installation Of Aerosol Based Fire Detection & Suppression System Cartrid Ge For Sg Ac Coaches. The Cartridge Contains 01 No. Of Minimum 40Gm For Power Panel, 02 No. Of Minim Um 15Gm For Rmpu Control Panel & 02 No. Of Minimum 10Gm For Inverter Panel Of Sg Ac Coaches As Per The Technical Requirement In Annexure-G1 Of Rdso Specification No. Rdso/Pe/Spec/Ac/0192-2018(Rev-1) & Rd So Letter No. El/7.1.108/Mssbc/Main Dated 12.05.2022. All Necessary Modification, Clamping Arrangement & Accessories Required For Installation Of This Item For Sg Ac Coaches Shall Be With The Scope Of This Supplier . Note: Location Of Installation Of Aerosol Fire Cartridge Shall Be As Per Rdso Letter No. El/7.1.108/Mssbc/ Main Dated 12.05.2022 & Cartridge May Be Provided In Line With Technical Parameters Note: Aerosol-Based Fire Detection & Suppression System Having Action Temperature Should Be 68-72 Degree Celsius As Per Late St Rdso L. No. El/7.1.108/Sbc/Main Dated 06.08.2025 [ Warranty Period: 30 Months After The Date Of Del Ivery ] ]